Nellcor-compatible SpO2 sensors — the OxiMax platform, covered properly
Nellcor compatibility is the deepest single-platform oximetry range in this catalogue, because Nellcor oximetry sits inside so many monitors: Covidien/Medtronic's own, and as the licensed oximetry module inside other brands' fleets. The compatible range (around fifty listed products) covers both sensor generations buyers must keep separate: OxiMax-type sensors (with the platform's digital memory in the sensor) and the pre-OxiMax pattern, plus the DOC-10 and DEC-8 cables that join them to their monitors.
The distinction is not pedantry. The platform's adapter cables (DOC-10 among them) cover specific sensor-and-monitor combinations within the Nellcor ecosystem; a standard sensor on an OxiMax monitor behaves differently again, and the exact combination for your fleet is confirmed before ordering. This page exists to make that three-way match — sensor generation, monitor generation, cable — explicit before money moves.
Compatible range
- Disposable sensors — adhesive adult/pediatric/neonatal (MAX-series patterns: MAX-A, MAX-I, MAX-N types)
- Reusable sensors — finger clip (7-pin patterns) and soft-tip, including D-YS-type multisite patterns
- Short sensors — for use with extension cables
- Adapter/extension cables — DOC-10 (OxiMax platform adapter) and DEC-8 (extension)
- Oximetry devices — Nellcor-platform pulse oximeters appear in the device range as a separate equipment line
Verifying a Nellcor match
State the monitor (or the module brand — many monitors carry Nellcor oximetry under another badge), whether the platform is OxiMax or earlier, and the sensor reference being replaced (MAX- and DS-series codes specify format and patient). With those three, sensor and cable are confirmed together — ordering them separately is how mismatches happen.
Representative compatible products (official store listings)
| Product (official store listing) | Key specifications |
|---|---|
| Covidien -Nellcor Compatible SpO2 Adapter Cable - DOC-10 | AMC: CB-A400-1011DO;Beta Biomed: B400-1011B;CAS Med: 01-02-0183;Covidien > Nellcor: DOC-10;GE Healthcare > Marquette: 2008773-001;Huntleigh: 320325-1;Mindray > Datascope: 0012-00-1464;Pacific Medical: NXNE500;Philips: M4780A;Sage: E06X-30M |
| Covidien > Nellcor Compatible Adult Clip Short SpO2 Sensor -DS100A | Avante Health Solutions: 80033NC;Covidien > Nellcor: DS-100A;DRE: DRE80033NC;Draeger: 7262764, MS13235;GE Healthcare > Marquette: 407705-006, 2023211-001, 70124021;Huntleigh: ACC-NEL-DS-100A;Mediaid: CST060-3120 (3 ft), CST060-31209 (9 ft); |
| Covidien > Nellcor Compatible Adult Soft Short SpO2 Sensor - FLEXMAX | Avante Health Solutions: 80033NC;Covidien > Nellcor: DS-100A;DRE: DRE80033NC;Draeger: 7262764, MS13235;GE Healthcare > Marquette: 407705-006, 2023211-001, 70124021;Huntleigh: ACC-NEL-DS-100A;Mediaid: CST060-3120 (3 ft), CST060-31209 (9 ft); |
| Covidien > Nellcor Compatible Direct-Connect Adult Clip SpO2 Sensor | Bitmos: sat 800, sat 801, sat 805, sat 816, satPuls;CAS Med: 511, 740;Cardio Aid: 200;Covidien > Nellcor: N-3000, N-390, N-395, N-550, N-560, N-595, N-600, N-6000, N-600x, NPB-290, NPB-295, Oximeters that require Nellcor OxiMax sensors, Sym |
| Covidien > Nellcor Compatible Direct-Connect Adult Soft SpO2 Sensor | Bitmos: sat 800, sat 801, sat 805, sat 816, satPuls;CAS Med: 511, 740;Cardio Aid: 200;Covidien > Nellcor: N-3000, N-390, N-395, N-550, N-560, N-595, N-600, N-6000, N-600x, NPB-290, NPB-295, Oximeters that require Nellcor OxiMax sensors, Sym |
| Covidien > Nellcor Compatible Direct-Connect Multi-site Y SpO2 Sensor | Bitmos: sat 800, sat 801, sat 805, sat 816, satPuls;CAS Med: 511, 740;Cardio Aid: 200;Covidien > Nellcor: N-3000, N-390, N-395, N-550, N-560, N-595, N-600, N-6000, N-600x, NPB-290, NPB-295, Oximeters that require Nellcor OxiMax sensors, Sym |
| Covidien > Nellcor Compatible Disposable SpO2 Sensor - I20 (Box of 24 ) | AMC: PR-E620-1011N (Microfoam Sensor), PR-E620-1013N (Microfoam Sensor);Covidien > Nellcor: I20;Envitec: DI-2411-5, DI-2211-5, DI-2271-5;Mediaid: CST034-2123 (36 in. / 90 cm);Philips: M1132A, 989803128541;Artema SandW: Diascope;Bionet: BM3, |
| Covidien > Nellcor Compatible Disposable SpO2 Sensor - MAX-I (Box of 24) | Covidien > Nellcor: MAX-I;Draeger: MX50067;GE Healthcare > Marquette: 70124026;Sage: DP063X-09M;Stryker > Medtronic > Physio Control: 11996-000115;Baxter: Explorer, Monarch;Biolight: M9500;Biosys: BPM-200, SENTRY;CAS Med: 511;Criticare: 506 |
OEM part numbers covered (selection)
| OEM part number | Compatible product | Full table |
|---|---|---|
| DS100A | Covidien > Nellcor Compatible Adult Clip Short SpO2 Sensor -DS100A | Cross-reference |
| 0010-10, 12392 | Covidien > Nellcor Compatible Short Adult Ear Clip SpO2 Sensor-0010-10-12392 | Cross-reference |
| M1191T | Covidien > Nellcor Compatible Short Adult Soft SpO2 Sensor-M1191T | Cross-reference |
| 2023215-001 | Covidien > Nellcor Compatible Short Multi-Site SpO2 Sensor - 2023215-001 | Cross-reference |
| M1193T | Covidien > Nellcor Compatible Short Neonate Soft SpO2 Sensor-M1193T | Cross-reference |
| 79061 | Covidien > Nellcor Compatible Short Pediatric Clip SpO2 Sensor-512H-30-79061 | Cross-reference |
| M1192T | Covidien > Nellcor Compatible Short Pediatric Soft SpO2 Sensor-M1192T | Cross-reference |
| M1192T | Covidien > Nellcor Compatible Short Pediatric Soft SpO2 Sensor-M1192T | Cross-reference |
All brand names, monitor model names and OEM part numbers on this page belong to their respective owners. They are used only to describe compatibility. Products offered here are third-party compatible accessories manufactured by Shenzhen Med-Link Electronics Tech Co., Ltd. under the Medlinket brand — not original equipment and not endorsed by the brand owner.
Questions & answers
What is the difference between OxiMax and standard Nellcor sensors?
OxiMax sensors carry a digital memory chip with the sensor's calibration and are used on OxiMax-platform monitors; earlier Nellcor platforms use the standard pattern. They are related but not freely interchangeable — specific combinations are covered by adapter cables such as DOC-10. Tell us your monitor generation.
Can I use these sensors on a non-Covidien monitor with Nellcor oximetry?
Yes — compatibility follows the oximetry platform, not the monitor badge. State the monitor model and module.
Are disposable MAX-type sensors boxed?
Yes — disposable adhesive sensors are supplied in boxes of 24.