EtCO2 accessories — sampling lines, water traps and cannulas
Capnography accessories are consumables with a failure clock: a sampling line occludes, a water trap saturates, and the waveform flattens long before the monitor itself is at fault. This focused range covers the sidestream pathway — nasal cannula sampling sets, sampling lines with luer-lock fittings, water traps (cross-referenced to OEM references such as Philips M2776A) and the sampling cells and modules the lines serve.
The range is deliberately narrow and deep rather than broad: EtCO2 accessory compatibility is module-specific, so every item is indexed to the capnography module or monitor family it serves, and the cross-reference carries the OEM numbers biomedical teams actually order by.

The sidestream pathway, part by part
In sidestream measurement the monitor aspirates a small gas sample through the line: cannula or airway adapter at the patient, line to the water trap, trap protecting the measurement cell. Each element has a distinct failure: cannulas kink and block with secretions; lines condense moisture on long runs; traps fill and trigger occlusion alarms. Stocking all three as one kit — as the catalogue's sampling-line kits do — keeps troubleshooting to a single swap.
- Sampling lines with luer-lock connectors, adult and pediatric
- Nasal cannula EtCO2 sets for non-intubated patients
- Water traps by module reference (e.g. M2776A type)
Specifying replacements
Name the module, not just the monitor: the same monitor brand ships with different capnography modules across generations, and the trap and cell fittings differ accordingly. The OEM part number of the trap or line being replaced is the surest identifier — send it and the match is confirmed before quotation. All lines and traps here are single-patient consumables.
Representative products from the current catalogue
| Product (official store listing) | Key specifications |
|---|---|
| GE Healthcare Compatible water trap D-Fend Pro-M1182629 (Box of 25pcs) | GE Healthcare: M1182629;Category: EtCO2;Patient Connector: Luer Connector;Latex-free: Yes;Packaging Unit: 25;Weight: 1.6 lb/Box;Application: Water Trape;Patient Size: Adult/Pediatirc;Sterile: No;Packaging Type: Box |
| GE Healthcare Compatible Dryline water trap- 8002174 (10pcs/box) | Mindray: 8002174;Category: EtCO2;Patient Connector: Luer Connector;Latex-free: Yes;Packaging Unit: 10;Weight: 0.04 lb/Box;Application: Water Trape;Patient Size: Adult/Pediatirc;Sterile: No;Packaging Type: Box |
| GE Healthcare Compatible Dryline water trap-402668-008 (20pcs/box) | GE Healthcare: 402668-008;Category: EtCO2;Patient Connector: Luer Connector;Latex-free: Yes;Packaging Unit: 1;Weight: 0.07 lb/pcs;Application: Water Trape;Patient Size: Adult/Pediatirc;Sterile: No;Packaging Type: Bag |
| GE Healthcare M1200227 Compatible Water Trap D-Fend Pro+ (Box of 25pcs) | GE Healthcare: M1200227;Category: EtCO2;Patient Connector: Luer Connector;Latex-free: Yes;Packaging Unit: 25;Weight: 1.60 lb/Box;Application: Water Trape;Patient Size: Adult/Pediatirc;Sterile: No;Packaging Type: Box |
| M2776A Compatible Single Use EtCO₂ Sampling Line for Philips LOFLO CO₂ Module, Adult/Pediatric/Infant/Neonatal, 2.5m (25pcs/box) | Compatible Manufacturer: OEM Reference #;Philips: M2776A;Category: EtCO₂ Sampling Line;Compatible OEM Part #: M2776A;Reference No.: CA20-093 / CBG00412;Patient Size: Adult, Pediatric, Infant, Neonatal;Total Length: 2.5m;Usage Duration: 12h; |
| Mainstream EtCO2 Sensor Philips Respironics Compatible with 8pin -Capnostat 5 | Bionet: B-RMCO2;Edan: M3B3002581;Infinium: 152.001.0002;Philips: Capnostat 5;Respironics: 1015928, 1050549;Spacelabs: 704-0165-00;Zoll: 8000-0312;Axia Surgical: V1050T;DRE: Waveline EZ, Waveline Pro;Hamilton Medical: C6 |
Questions & answers
Mainstream or sidestream?
This range serves sidestream capnography (sample drawn through a line to the module). Tell us your module model and we confirm the line and trap set.
How do I identify the right water trap?
By the module reference — for example the M2776A-type trap used on Philips sidestream modules. The trap's OEM number is printed on the part; send it for an exact match.
Are sampling lines reusable?
No — sampling lines, cannulas and water traps are single-patient consumables.
See also: Mainstream vs sidestream capnography · Philips-compatible accessories · Ask for a module match