Philips-compatible accessories — SpO2, ECG, NIBP, temperature, IBP
Philips is one of the three deepest compatibility ranges in the catalogue: more than 125 listed products spanning SpO2 sensors and cables, ECG leadwires, NIBP cuffs, temperature probes, IBP cables and EtCO2 accessories for the IntelliVue, SureSigns, Avalon and legacy HP/Agilent-generation monitors that still fill wards worldwide. The range is organised around Philips' own accessory logic — sensor families by patient (the M1193A adult silicone-soft pattern and M1193T neonatal wrap pattern are representative references), 8-pin and FAST-SpO2 generations kept distinct.
Philips platforms reward precision in ordering: the same monitor family spans several oximetry and connector generations, and Philips' own part numbers encode the differences. That is why this page, like the catalogue behind it, is indexed by those numbers — Philips references run throughout the cross-reference — rather than by generic descriptions.
Compatible range by category
- SpO2 sensors — disposable and reusable, adult to neonatal (M1193A/M1193T-type references)
- SpO2 cables and adapters — extension and interconnect patterns
- ECG leadwires and trunk cables — 3/5-lead monitoring and 12-lead sets
- NIBP cuffs and hoses — full size range, Philips fittings
- Temperature probes — skin and disposable types
- IBP cables — transducer interfaces for Philips pressure inputs
- EtCO2 — sidestream water traps (M2776A type) and sampling lines
Verifying a Philips match
Give us the monitor model (IntelliVue generation matters), the module if the parameter is modular, and the M-reference of the accessory being replaced. Philips references are precise enough to specify sensor, patient size and cable in one code, so a single M-number usually closes the verification in one step.
Representative compatible products (official store listings)
| Product (official store listing) | Key specifications |
|---|---|
| Covidien -Nellcor Compatible SpO2 Adapter Cable - DOC-10 | AMC: CB-A400-1011DO;Beta Biomed: B400-1011B;CAS Med: 01-02-0183;Covidien > Nellcor: DOC-10;GE Healthcare > Marquette: 2008773-001;Huntleigh: 320325-1;Mindray > Datascope: 0012-00-1464;Pacific Medical: NXNE500;Philips: M4780A;Sage: E06X-30M |
| Covidien > Nellcor Compatible Adult Soft Short SpO2 Sensor - FLEXMAX | Avante Health Solutions: 80033NC;Covidien > Nellcor: DS-100A;DRE: DRE80033NC;Draeger: 7262764, MS13235;GE Healthcare > Marquette: 407705-006, 2023211-001, 70124021;Huntleigh: ACC-NEL-DS-100A;Mediaid: CST060-3120 (3 ft), CST060-31209 (9 ft); |
| Nellcor Disposable SPO2 Sensor Compatible Non-Adhesive for Neonate/Adult-N25/M1133A | Covidien > Nellcor: N25;Envitec: DN-2411-6, DN-2211-6, DW-2211-6 (Disposable Sensor Wrap), DN-2271-6, DW-2271-6 (Foam);GE Healthcare > Marquette: 2023216-001;Philips: M1133A, 989803128551, M1134A, 989803164921;Artema SandW: Diascope;Bionet: |
| Philips (Masimo) Compatible SpO2 Adapter Cable - 989803148221 (with Masimo LNCS tech.) | Masimo: 2270,LNC MP10,2281,3755 (4 ft);Philips: 989803148221;Sage: E10-708MP;Category: SpO2;Connector Distal: Philips 8-pin D-Shaped Male Connector;Total Cable Length: 8ft (2.4m);Cable Material: TPU Jacket;Packaging Unit: 1;Weight: 0.4lb;Sp |
| Philips Compatible Short Infant Silicone Soft SpO2 Sensor | ARI: 800B;Advanced Instrumentations: PM-2000A Pro, PM1000F;Artema SandW: Diascope;Bionet: BM3, BM3 Plus, BM7Vet;Bionics: BPM-200;Biosys: BPM-200, SENTRY;Carewell: CPM-9000T;Covidien > Nellcor: N-10, N-100, N-180, N-190, N-20, N-200, N-30, N |
| Philips Compatible Direct-Connect Adult Clip SpO2 Sensor - M1196A | Beta Biomed: B505-1006V-10;Philips: M1196A, 989803128631, 989803174381 (2 m), M1196S (2 m);Sage: P01-30M;Goldway: G40;Solaris: NT2A, NT2C;Category: SpO2;Connector Distal: Philips 8-pin D-Shaped Male Connector;Total Cable Length: 10 ft (3m); |
| Philips Compatible Direct-Connect Adult Ear Clip SpO2 Sensor - M1194A | Envitec: ES-2414-15 (5 ft (1.5 m));Philips: M1194A, 989803103251;Sage: P019-11M;Goldway: G40;Solaris: NT2A, NT2C;Category: SpO2;Connector Distal: Philips 8-pin D-Shaped Male Connector;Total Cable Length: 10 ft (3 m);Cable Material: TPU Jack |
| Philips Compatible Direct-Connect Adult Soft SpO2 Sensor - M1191BL | AMC: PR-A900-1006V;Envitec: R-2414-30, R-2414-30plus (Autoclavable);Pacific Medical: NSPH200;Philips: M1191BL, M1191AL;Tenacore: TP1503SP-10;Goldway: G40;Solaris: NT2A, NT2C;Category: SpO2;Connector Distal: Philips 8-pin D-Shaped Male Conne |
OEM part numbers covered (selection)
| OEM part number | Compatible product | Full table |
|---|---|---|
| M1872B | Disposable Pet Blood Pressure Cuff | Philips M1872B Compatible NIBP | Cross-reference |
| M1866A | M1866A Neonatal Cuff | Philips/Welch Allyn Compatible TPU NIBP #1 | Cross-reference |
| M1866S | M1866S Neonatal Cuff Replacement for Philips | Disposable TPU NIBP #1 | Cross-reference |
| M1868B | M1868B Neonatal Cuff Compatible with Philips | Soft Disposable NIBP #2 | Cross-reference |
| M1872A | M1872A Neonatal Cuff | Philips/Welch Allyn Compatible TPU NIBP #4 | Cross-reference |
| M2776A | M2776A Compatible Single Use EtCO₂ Sampling Line for Philips LOFLO CO₂ Module, Adult/Pediatric/Infant/Neonatal, 2.5m (25pcs/box) | Cross-reference |
| M3702C | M3702C Philips Direct-Connect EKG Cables Compatible With 10 Leads 4mm Banana AHA | Cross-reference |
| M3703C | M3703C Philips Direct-Connect EKG Cables Compatible With 10 Leads 4mm Banana IEC | Cross-reference |
All brand names, monitor model names and OEM part numbers on this page belong to their respective owners. They are used only to describe compatibility. Products offered here are third-party compatible accessories manufactured by Shenzhen Med-Link Electronics Tech Co., Ltd. under the Medlinket brand — not original equipment and not endorsed by the brand owner.
Questions & answers
Do you cover older HP/Agilent-generation monitors?
Yes — legacy Philips/HP-platform accessories are part of the range; give the monitor model and the accessory reference.
Which Philips SpO2 sensor fits an IntelliVue?
It depends on the oximetry generation and patient: send the monitor model and your current sensor's M-reference and the match is confirmed before quotation.
Are the water traps for Philips modules stocked?
Yes — M2776A-type sidestream water traps are in the EtCO2 range.
See also: SpO2 sensors · EtCO2 accessories · Cross-reference