Nonin-compatible oximeter probes and SpO2 sensors
Nonin is a single-parameter specialist: its name is attached to handheld and tabletop pulse oximeters (the 2500 PalmSat class of device is the familiar reference point) and to OEM oximetry modules inside other manufacturers' equipment. The compatible range is correspondingly focused — a compact line of Nonin-compatible probes and sensors: finger clips, soft sensors and disposables matched to Nonin device connectors.
Nonin devices routinely outlive their original sensors by years, and the replacement probe must match Nonin's connector and sensor specification rather than a generic oximeter plug — the reason this focused compatible line exists.
Gamme compatible
- Reusable finger-clip probes — adult, for Nonin handheld/tabletop devices
- Soft-tip sensors — longer-wear and pediatric use
- Disposable sensors — Nonin-platform adhesive formats
- Module applications — sensors for equipment carrying Nonin OEM oximetry (state the host device)
Verifying a Nonin match
Give the device model (or the host device and its module, for embedded applications) and the sensor reference if the old probe carries one. Nonin connectors differ across device generations; a socket photograph removes the ambiguity in one step. As everywhere on this site: these are Medlinket-manufactured compatible accessories, not Nonin products.
Produits compatibles représentatifs (fiches de la boutique officielle)
| Produit (fiche de la boutique officielle) | Spécifications clés |
|---|---|
| Nonin 2000SL Veterinary SpO2 Sensor Compatible with Tongue Clip for pulse oximeter-3ft | Nonin: 2000SL;Category: SpO2;Monitor End Connector: Male 9PIN;Total Cable Length: 3ft (1m);Cable Material: TPU Jacket;Packaging Unit: 1;Weight: 0.15lb;SpO2 Tech: Nonin;Patient End Connector: Y Type Multisite;Patient Size: All Vet sizes |
| Nonin 8000aa SpO2 Sensors Compatible with Adult Finger Clip 0.9m | AMC: PR-A520-1014N;Beta Biomed: B505-1014;CAS Med: 01-02-0250 (Adult Clip 2 Meter Cable), 01-03-0117 (Adult Clip 3 Meter Cable);Envitec: F-3012;Mindray > Datascope: 100-000077-00, 0600-00-0140-01;Nonin: 3278-001, 3278-003 (3 m), 3278-006 (2 |
| Nonin 8000AP SpO2 Sensors Compatible with Pediatric Finger Clip 0.9m | AMC: PR-A120-1014N;CAS Med: 01-03-0121, 01-02-0106 (Pediatric Clip 3 Meter Cable);Nonin: 8000AP, 8000AP-1, 2360-000;Respironics: 936P;Welch Allyn: 2360-010;Healthdyne: 930, 9705, 970S, 970SE;Mindray > Datascope: BeneVision TD60, BeneVision |
| Nonin 8000Q2 SpO2 Sensors Compatible with Adult Ear Clip 1.2m | AMC: PR-A220-1014N;CAS Med: 01-02-0108;Envitec: ES-3012;Nonin: 6455-000, 8000Q2;Healthdyne: 930, 9705, 970S, 970SE;Mindray > Datascope: BeneVision TD60, BeneVision TMS60, BeneVision TMS80, Panorama Telepack 608;ResMed: ApneaLink Air, Astral |
| Nonin 8000SL SpO2 Sensors Compatible with Adult Soft 1.2m | Envitec: R-3012, R-3012plus (Autoclavable);Nonin: 8000SL (Large Soft Sensor (12.5 - 25.5 mm digit)), 8000SL-3 (3 m) (Large Soft Sensor (12.5 - 25.5 mm digit)), 6835-000, 6836-300;Philips: 1062049;CAS Med: OscilloMate 9002, OscilloMate 9302S |
| Nonin 8000SM SpO2 Sensors Compatible with Pediatric silicone soft | Envitec: RM-3012, RM-3012plus (Autoclavable);Nonin: 8000SM (Medium Soft Sensor (10 - 19 mm digit)), 6836-000;Philips: 1062050;CAS Med: OscilloMate 9002, OscilloMate 9302S, OscilloMate 9303;Healthdyne: 930, 9705, 970S, 970SE;Mindray > Datasc |
Tous les noms de marques, noms de modèles de moniteurs et références pièces OEM sur cette page appartiennent à leurs détenteurs respectifs. Ils sont utilisés uniquement pour décrire la compatibilité. Les produits proposés ici sont des accessoires compatibles tiers fabriqués par Shenzhen Med-Link Electronics Tech Co., Ltd. sous la marque Medlinket — ils ne sont pas un équipement d'origine et ne sont pas approuvés par le propriétaire de la marque.
Questions et réponses
My Nonin device is old — are probes still available?
The compatible line covers the common Nonin device generations; send the model and connector photo and we confirm.
Handheld device or module — does it change the sensor?
The connector and specification follow the device/module generation, so yes, state which you have.
Are pediatric Nonin-compatible sensors stocked?
Soft-format sensors suitable for smaller patients are in the line; state the patient range when ordering.